The importance of electrical explosion-proof testing 

Now, we need to place greater importance on safety testing and inspection work, constantly introducing new safety testing methods and instruments, and promoting the continuous development of electrical explosion-proof safety testing technology. Conducting electrical explosion-proof safety testing in hazardous areas means testing and confirming the safety and reliability of the explosion-proof performance of electrical facilities and equipment operating in hazardous areas. In such hazardous areas, many places can produce explosive gases, some can produce combustible dust, etc. Through those with safety production testing and inspection qualificationsZhongnuo TestingInstitutions shall not dismantle or only partially dismantle the tested facilities and equipment in hazardous areas, and shall supplement them with relevant testing measures. They shall conduct safety inspections on potential hazards of electrical explosion-proof facilities in hazardous chemical areas, control them early, and provide technical support for the safe operation of hazardous chemical enterprises.


The content of electrical explosion-proof safety testing

Conducting electrical explosion-proof testing in hazardous areas, mainly including transformer and distribution systems; Electrical circuit system; Selection of explosion-proof electrical equipment; Infrared testing for overheating conditions; Grounding system and grounding resistance detection; Ultrasonic leakage discharge testing involves the inspection and testing of all electrical explosion-proof safety facilities within the explosion-proof area. In various hazardous areas, explosion-proof safety testing is usually carried out on electrical equipmentZhongnuo TestingOnce problems are found with the electrical equipment model, installation, operation, wiring, grounding, etc., a written report should be immediately issued to the relevant enterprise. At the same time, contact should be made with the safety supervision department to urge the enterprise to take corrective actions. The ultimate goal is to ensure that the explosion-proof testing and inspection of electrical equipment in hazardous areas meet the qualified standards.


Form of electrical explosion-proof safety testing in hazardous areas

1. Model detection

According to the strict regulations of relevant national laws, the explosion-proof labeling of explosion-proof electrical equipment must be standardized, and it can only be implemented after passing the inspection of the national quality inspection department. Design appropriate explosion-proof types, explosion-proof levels, and temperature groups for electrical equipment based on specific working environments.

 

2. Installation testing

During the installation of electrical equipment, any carelessness can lead to potential losses. If the ventilation and exhaust system is not properly installed and not very smooth, there is also a possibility of explosions in the casing of electrical equipment during electrical operation. So when installing, we must strive for excellence and install according to relevant standards.


3. Line detection

Electrical equipment is often composed of a large number of connected circuits, which are particularly complex. If the connections are not solid, or if there are incorrect connections, or if the insulation layer of the circuit falls off, it may cause short circuits or overloads, resulting in arcing or electric sparks. So, it is necessary to strengthen the inspection of the circuit, especially the sealing of the circuit, to ensure that the connection of the circuit meets the requirements.

 

4. Grounding detection

Electrical equipment generates static electricity during operation. If there is too much static electricity, sparks may occur during discharge. Therefore, grounding protection measures should be taken to timely discharge the static electricity and prevent explosions. The usual grounding methods include three types: working grounding, electrostatic grounding, and lightning protection grounding. For engineers, it is necessary to choose the grounding method according to the specific working environment, and the grounding should be safe and firm.

 

Chemical enterprises must regularly maintain and inspect explosion-proof electrical and anti-static facilities in hazardous areas during their production, ensuring that they always operate in normal working condition. For hazardous areas, electricalExplosion proof safety testingWe should follow scientific development, keep pace with the times, strengthen the discovery and invention of new detection methods and means, continuously apply new knowledge and technology, as well as management methods, prevent hidden dangers, and eliminate exposed unsafe factors.




Related Recommendations
Contact us
0755-2102 2109
Add: 13F, Building C, Kangjia Guangming Technology Center, No. 288 Xingxin Road, Guangming District, Shenzhen
Follow us
Copyright: Shenzhen Zhongnuo Testing Technology Co., Ltd. 粵ICP備18004888號
Service Hotline
18924609560
點擊這里給我發消息 1354407946
點擊這里給我發消息 1354407946
主站蜘蛛池模板: 男女日皮免费视频 | 99re在线视频播放 | 亚洲妇人成熟性成熟网站 | 国产福利不卡一区二区三区 | 日韩欧美国产高清 | 欧美日韩在线视频一区 | 精品乱久久 | jizz中国zz女人18| 午夜影院网页 | 日日射日日干 | 欧美日韩亚洲一区二区三区在线观看 | 日韩在线高清 | 美女视频黄a视频全免费应用 | 婷婷人人爽人人爽人人片 | 精品三级网站 | 日韩字幕在线 | 欧美一区二区三区不卡免费 | 爱做久久久久久久久久 | 性久久久久 | 国产福利二区 | 人人洗澡人人洗澡人人 | 欧美综合一区二区三区 | 青青操国产视频 | 欧美日韩一区二区三区高清不卡 | 好看毛片 | 国产成人精品久久一区二区小说 | 欧美大成色www永久网站 | 欧美成人性色xxxx视频 | 欧美肉到失禁高h视频在线 欧美三级 欧美一级 | 精品视频一二三区 | 免费人成网站永久 | 久久狠狠一本精品综合网 | 欧美老妇人v片 | 精品九九九 | 久久久精品久久久久久久久久久 | 亚洲综合色婷婷在线观看 | 亚洲午夜一区二区三区 | 九九视频在线看精品 | 97人人做人人爽人人喊 | 成人的天堂视频一区二区三区 | 天天久久综合网站 |