The IEC standard corresponding to GB/T3836-2021 standard

SINO Testing Services

| 2022-06-27|Return

With the release and implementation of the new version of the national standard GB/T3836-2021, domestic explosion-proof standards have further aligned with international explosion-proof standards. The new version of the national explosion-proof standard combines the original GB12476 and GB25286 standards, covering various aspects such as design, manufacturing, inspection, selection, installation, inspection, maintenance, repair, and site classification of equipment used in explosive environments. It adopts a segmented standard form, including but not limited to the following parts.

GB/T 3836.1-2021 Explosive Atmosphere Part 1: General Requirements for Equipment

Corresponding IEC standards: IEC 60079-0: 2017 Explosive Atmosphere Part 0: General Requirements for Equipment

GB/T 3836.2-2021 Explosive Atmosphere Part 2: Equipment Protected by Flameproof Enclosures "d"

Corresponding IEC standards: IEC 60079-1: 2014 Explosive Environments Part 1: Equipment Protected by Explosion proof Enclosures "d"

GB/T 3836.3-2021 Explosive Atmosphere Part 3: Equipment Protected by Increased Safety Type "e"

Corresponding IEC standards: IEC 60079-7: 2015 Explosive Atmosphere Part 7: Equipment Protected by Increased Safety Type "e"

GB/T 3836.4-2021 Explosive Atmosphere Part 4: Equipment Protected by Intrinsic Safety Type "i"

Corresponding IEC standards: IEC 60079-11: 2011 Explosive Atmosphere Part 11: Equipment Protected by Intrinsic Safety Type "i"

GB/T 3836.5-2021 Explosive Atmosphere Part 5: Equipment Protected by Positive Pressure Housing "p"

Corresponding IEC standards: IEC 60079-2: 2014 Explosive Atmosphere Part 2: Equipment Protected by Positive Pressure Shell "p"

GB/T 3836.6-2017 Explosive Atmosphere Part 6: Equipment Protected by Liquid Immersion Type "O"

Corresponding IEC standards: IEC 60079-6: 2015 Explosive Atmosphere Part 6: Equipment Protected by Liquid Immersion Type "O"

GB/T 3836.7-2017 Explosive atmospheres - Part 7: Equipment protected by sand filled molds "q"

Corresponding IEC standards: IEC 60079-5: 2015 Explosive Atmosphere Part 5: Equipment protected by sand filled mold "q"

GB/T 3836.8-2021 Explosive Atmosphere Part 8: Equipment Protected by "n" Type

Corresponding IEC standards: IEC 60079-15: 2017 Explosive Atmosphere Part 15: Equipment Protected by "n" Type

GB/T 3836.9-2021 Explosive Atmosphere Part 9: Equipment Protected by Sealed Type "m"

Corresponding IEC standards: IEC 60079-18: 2014 Explosive Atmosphere Part 18: Equipment Protected by Sealed Type "m"

GB/T 3836.11-2017 Explosive Atmosphere Part 11: Classification Test Methods and Data for Characteristics of Gas and Vapor Substances

Corresponding IEC standards: IEC 60079-20-1: 2010 Explosive Atmosphere Part 2-1: Classification Test Methods and Data for Gas and Vapor Substances Characteristics

GB/T 3836.12-2019 Explosive Atmosphere Part 12: Test Methods for Characteristics of Combustible Dust Substances

Corresponding IEC standards: ISO/IEC 80079-20-2: 2016 Explosive Atmosphere Part 20-2: Material Characteristics Combustible Dust Test Method

GB/T 3836.13-2021 Explosive Atmosphere Part 13: Equipment Repair, Maintenance, Restoration and Modification

Corresponding IEC standards: IEC 60079-19: 2019 Explosive Environment Part 19: Repair, Maintenance, and Restoration of Equipment

GB 3836.14-2014 Explosive Atmosphere Part 14: Site Classification Explosive Gas Atmosphere

Corresponding IEC standards: IEC 60079-10-1: 2008 Explosive Atmosphere Part 10-1: Classification of Hazardous Areas Explosive Gas Atmosphere

GB/T 3836.15-2017 Explosive Atmosphere Part 15: Design, Selection and Installation of Electrical Installations

Corresponding IEC standards: IEC 60079-14: 2007 Explosive Atmosphere Part 14: Design, Selection, and Installation of Electrical Installations

GB/T 3836.16-2017 Explosive Atmosphere Part 16: Inspection and Maintenance of Electrical Installations

Corresponding IEC standards: IEC 60079-17: 2007 Explosive Atmosphere Part 16: Inspection and Maintenance of Electrical Installations

GB/T 3836.17-2019 Explosive Atmosphere Part 17: Equipment Protected by Positive Pressure Room "p" and Artificially Ventilated Room "v"

Corresponding IEC standards: IEC 60079-13: 2017 Explosive Atmosphere Part 13: Equipment Protected by Positive Pressure Room "p" and Artificially Ventilated Room "v"

GB/T 3836.18-2017 Explosive Atmosphere Part 18: Intrinsically Safe Electrical Systems

Corresponding IEC standards: IEC 60079-25: 2010 Explosive Atmosphere Part 25: Intrinsically Safe Electrical Systems








Related Recommendations
Contact us
0755-2102 2109
Add: 13F, Building C, Kangjia Guangming Technology Center, No. 288 Xingxin Road, Guangming District, Shenzhen
Follow us
Copyright: Shenzhen Zhongnuo Testing Technology Co., Ltd. 粵ICP備18004888號
Service Hotline
18924609560
點擊這里給我發消息 1354407946
點擊這里給我發消息 1354407946
主站蜘蛛池模板: 精品女同一区二区三区免费站 | 毛片毛多| 国产精选一区二区 | 欧美久久伊人 | 依依成人综合 | 天天干视频网站 | 五月天开心婷婷 | 日本黄视频网站 | 日本特黄色大片 | 国产在线精品二区韩国演艺界 | 欧美激情视频二区三区 | 免费成人高清 | 另类ts人妖一区二区三区 | 日本又黄又爽又免费 | 免费jizz在线播放 | 色吊丝国产永久免费网址 | 久久国产精品久久国产片 | 91久久夜色精品国产九色 | 国产成人精品永久免费视频 | 国产噜噜噜精品免费 | 欧美手机在线视频 | 人人澡人人爱 | 久久免费视频2 | 日本免费影院 | 高清欧美不卡一区二区三区 | 91热精品 | 女人毛片a毛片久久人人 | 欧美性色高清生活片 | 日韩视频在线观看 | 一级毛片一级毛片免费毛片 | 国产黑料不打烊 | 久久久久免费视频 | 色aaa| 久久精品国产日本波多麻结衣 | 国产精品乳摇在线播放 | 国产精品久久久久久久久久影院 | 亚洲好视频 | 免费在线国产视频 | 国产成人免费高清激情明星 | 久草福利资源网站免费 | 越南三级dvd在线播放 |